sigma logo

PS7 GETTER AND ADSORBER HYDROGEN PURIFIER




The MegaTorr PS7 Series Getter and Adsorber Gas purifiers utilize a combination of heated getter and ambient catalytic-adsorption processes to provide ultra-high purity Hydrogen gas. Outlet impurity levels for O2, CO, CO2, H2O, CH4, NMHC, and N2.

Two ambient temperature adsorber vessels removes O2, CO, CO2 and H2O while the downstream getter vessel, operated at an elevated temperature, eliminates N2 and CH4. The two adsorber vessels alternate between purify and regeneration mode providing continuous purification. Adsorber regeneration is accomplished by backflushing with purified hydrogen at elevated temperatures.

FEATURES


STANDARD FEATURES
  • Automated Microprocessor Controller
  • CRT Touchscreen Operator Interface
  • Password Protected Control System
  • System Alarms
  • Temperature Interlocks
  • N2 Purged Secondary Enclosure
  • H2 Leak Detection Sensor
  • Vented Cabinet Purge
  • Over Pressurization Safety Relief System
  • Electric Gas Preheater
  • Dual Closed-Loop Temperature Controls
  • Redundant Heating Elements
  • Pressure Transducers
  • Battery Back-up
  • Back-up Pneumatics Reservoir
  • Water Cooled Heat Exchanger
  • All Metal Enclosure With Doors


CUSTOMER INTERFACE CONNECTIONS
  • Alarm Relay - fail safe relay contacts allow remote detection of alarm condition.
  • Remote Contact Shutdown - allows remote shutdown of the purifier.
  • Mass Flow Meter & Totalizer 4-20mA - Available when MFM is specified.


OPTIONAL FEATURES
  • Mass flow meter with 4-20mA Output
  • Internal Auto Bypass
  • Separate Control Power
  • UPS - Uninterruptible Power Supply


PS7 Adsorber and Getter - Performance

Gas Purified Impurities Removed Outlet Performance
H2 H2O, O2, CO, CO2, N2, NMHC < 1 ppb
CH4 < 10 ppb (at factory), <1 ppb (on-site)
Note: Purifiers are gas specific and should only be used for the gas indicated


PS7 Adsorber and Getter - Specification

 Model Maximum Flow (Nm3/hr) Average Power Consumption (kW) Maximum Pressure Drop (bar) Cooling Water (lpm) Dimensions (cm) Weight (kg)
H W D
 PS7-MGT20-H  20 4  0.7 10 205 161 120  862
 PS7-MGT40-H  40 8 1 20 205 161 120  862
 PS7-MGT100-H  100  22 1.2 40 213 134 164  1361


Pictures (click to enlarge)